Wiring diagram
Draw how your machine is wired to the board. Every rule cites its source. This page never talks to a machine, and it does not replace a qualified electrician.
TinyG v6 and v7 have no connector data yet, so they have no diagram.
Parts
No parts yet.
Connect
| Wire | From | To | Shielded | Actions |
|---|
INCOMPLETE — NO E-STOP SHOWN
Findings (1)
- E-STOP WR-ESTOP No E-stop is shown. Exports carry the "INCOMPLETE — NO E-STOP SHOWN" watermark and "wired per diagram" cannot be attested. Source: SAFETY W14; TOOLS_PLAN §6.5 E-STOP rule
Expected settings (advisory)
Each key is accepted on its own into the settings draft. Nothing is written to a machine here.
xsn = 0nothing on Xmin (J7.3): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])xsx = 0nothing on Xmax (J7.4): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])ysn = 0nothing on Ymin (J7.5): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])ysx = 0nothing on Ymax (J7.6): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])zsn = 0nothing on Zmin (J8.3): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])zsx = 0nothing on Zmax (J8.4): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])asn = 0nothing on Amin (J8.5): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])asx = 0nothing on Amax (J8.6): off Source: EN canonical_machine.c:3174-3175 ([0=off,1=homing,2=limit,3=limit+homing,4=probe])
Settings draft: empty
Export and checklist
- Switch off and unplug every supply before wiring. Keep power off until the last step. Source: TOOLS_PLAN §6.5 checklist
- Check the polarity and voltage of every supply with a meter before connecting it to the board. Source: TOOLS_PLAN §6.5 checklist
- Connect or disconnect motors only with power off: power off, connect the motors, then power on. Never plug or unplug a motor with power on. Source: SAFETY C6 note; CIT-3
- Wire the motor phases by the labels printed on the board; the diagram follows the board print. Source: TOOLS_PLAN §6.5 (TinyG v8 phase order not verified)
- Turn the current trimpots only within their range: about 8 o’clock to about 4 o’clock (270 degrees). Never force them past the stops. Source: TinyG.wiki TinyG-Tuning.md:23; Connecting-TinyG.md:144
- Check every connection against the wire table, then power on. Source: TOOLS_PLAN §6.5 checklist
Not available: no E-stop that removes motor and spindle power is shown.